| Availability: | |
|---|---|
The Pharmaceutical Steam Sterilizer Autoclave combines pre-vacuum air removal, saturated steam sterilization and vacuum drying in one automatic cycle, helping achieve more consistent steam penetration and efficient load processing.
Cycle:
Loading → Pre-Vacuum → Steam Sterilization → Exhaust → Vacuum Drying → Cooling → Unloading
Cycle parameters can be configured according to load type and validated process requirements.
SUS304 inner chamber for durable, easy-clean operation
Double-layer chamber supports stable heating and drying
Cylinder-driven door locking for smooth operation
Mechanical + electrical interlocks enhance operational safety
High-temperature silicone seal supports reliable chamber sealing
Thermal insulation helps reduce heat loss
Value: Designed for repeated pharmaceutical sterilization cycles with stable operation, easier cleaning and reduced maintenance effort.
The PLC and touchscreen system simplifies sterilization cycle management with:
Temperature and pressure monitoring
Automatic vacuum and sterilization control
F0 management
Cycle curve recording
Alarm monitoring
Data storage and printing
Value: Operators can manage key sterilization parameters from one interface while maintaining clearer production records and reducing manual operation.
The built-in Bowie-Dick test program supports routine air-removal and steam-penetration checks.
Project support can include:
FAT / SAT
Calibration
IQ / OQ support
Cycle documentation
Validation-related technical support
Value: Helps simplify equipment qualification and pharmaceutical project handover.
For biological and high-containment applications, optional configurations can include:
Pressure-holding inactivation
Inactivation tank
Exhaust treatment
Customized containment design
Value: Flexible configuration allows the sterilizer to adapt to more demanding pharmaceutical and laboratory applications.
For sterilization of heat-resistant pharmaceutical materials, containers and production accessories.
Suitable for laboratory instruments, glassware and other steam-compatible loads.
For medical and clinical sterilization processes requiring controlled saturated steam cycles.
Suitable for selected bottles, cans and flexible packages that can tolerate high-temperature steam sterilization.
Optional configurations can support specialized biological containment sterilization requirements.
Parameter | Specification |
|---|---|
Sterilization Medium | Saturated Steam |
Sterilization Type | Pre-Vacuum / Pulse Vacuum |
Typical Temperature | Up to 132°C+ according to cycle |
Typical Pressure | Approx. 205.8 kPa in described cycle |
Chamber Type | Horizontal Rectangular |
Inner Chamber Material | SUS304 |
Door Configuration | Double Door |
Door Lock | Cylinder Driven + Safety Interlock |
Control System | PLC + Touchscreen |
Operation | Automatic / Manual |
F0 Management | Preset / Display / Print |
Vacuum Drying | Supported |
B.D. Test | Supported |
Validation Interface | Available |
Inactivation System | Optional |
MAYA provides sterilization equipment together with pharmaceutical process equipment, filling systems and cleanroom engineering solutions. The current product is categorized under Sterilization & Washing Equipment.
Configurations can be developed according to chamber capacity, sterilization load, door arrangement, drying requirements and validation needs.
Support includes:
Equipment selection
Technical consultation
2D / 3D design
Equipment customization
FAT / SAT
Validation support
Installation
Commissioning
Operator training
Technical documentation
Support includes:
Remote troubleshooting
On-site technical service
Spare parts
Maintenance guidance
Operator support