| Availability: | |
|---|---|
The isolator provides a closed handling environment for potent pharmaceutical materials that require strict operator protection.
Typical operations include:
Material Transfer → Weighing / Dispensing → Processing / Feeding → Waste Collection → Decontamination
Operators work through glove ports without directly opening the chamber, while the negative-pressure system maintains inward airflow to help keep hazardous particles inside the containment area.
The isolator maintains a controlled negative-pressure environment during hazardous material handling.
The airflow system automatically monitors pressure conditions and adjusts fan operation when needed, helping prevent hazardous particles from escaping.
Key Benefits:
Protects operators during high-potency material handling
Reduces contamination risks in cleanroom areas
Supports safer pharmaceutical processing
The isolator supports secure material transfer while maintaining containment integrity.
Available configurations include:
RTP Transfer: Closed transfer ports for safe material loading and unloading
Bagging System: Contained waste discharge for contaminated materials
Customized Interfaces: Integration with upstream and downstream equipment
The chamber is designed for easier cleaning and residue control after processing.
Features include:
WIP cleaning system
Inclined chamber bottom
Smooth 316L / PTFE internal surfaces
Reduced dead corners and residue accumulation
Easy drainage design
This helps simplify decontamination and reduce manual cleaning requirements.
The PLC-based control system monitors key operating parameters for stable operation.
Monitoring options include:
Chamber pressure
Temperature and humidity
Oxygen concentration
Door and seal status
Filter condition
Alarm status
SCADA integration and data recording are available for centralized monitoring and process management.
Parameter | Specification |
|---|---|
Equipment Type | Negative Pressure Containment Isolator |
Containment Level | Up to OEB 5 |
OEL | <1 μg/m³ |
Leakage Rate | <0.001 vol%/h |
Operating Mode | Negative Pressure |
Airflow | Controlled Vertical Airflow |
Emergency Inward Air Velocity | >0.5 m/s at leakage point |
Inner Chamber Material | 316L Stainless Steel / PTFE |
Surface Finish | Ra 0.4–0.6 μm |
Cleaning System | WIP Available |
Material Transfer | RTP Available |
Waste Discharge | Bagging System Available |
Control System | PLC + HMI |
SCADA Integration | Available |
Environmental Monitoring | Temperature / Humidity / O₂ according to configuration |
Explosion-Proof Design | Optional |
Door Seal Monitoring | Supported |
MAYA can configure isolator dimensions, glove-port layout, RTP systems, filtration and process interfaces according to actual operation requirements.
Support includes:
Mock-up
3D design
FAT / SAT
IQ / OQ / PQ support
Installation
Commissioning
Operator training
Documentation
Support includes:
Remote troubleshooting
On-site support
Spare parts
Filter replacement support
Maintenance guidance